Part Number
KRN50
50mm Compact Hybrid Recorder & Data Logger in One
Manufacturer: Autonics
Technical Specification

Powe supplyAC voltage
100-240 VAC 50 to 60 Hz
Allowable voltage rangeAC voltage
85 to 110% of rated voltage
Power consumptionAC voltage
Max. 34 VA
Display method
LCD Dot matrix Display (resolution 128 x 32 Dot)
TC
K, J, E, T, B, R, S, N, C, G, L, U, PLII (13 types)
Contact
Input ON: Max. 1 k, OFF: Min. 100 k
Outflow current
Approx. 0.3 mA
TC
0.2%F.S.1digit(255 ), 0.3%F.S.1digit(0 to 20 , 30 to 50 ) Below -100 for TC is 0.4%F.S.1digit (TC-K2 has same accuracy with TC-K1 and -200 to 1350 range
Record accuracy
0.5%F.S.
Alarm output hysteresis
ON/OFF interval setting for alarm output: 1 to 999digit variable
Powe supplyDC voltage
24 VDC
DC voltage
90 to 110% of rated voltage
Power consumptionAC voltage
Max. 79 W
RTD
JPt100, DPt100, DPt50, Cu100, Cu50 (5 types)
Analog
Voltage: -50.0~50.0 mV, -199.0~200.0 mV, -1.000~1.000 V, -1.00~10.00 V (4 types) Current: 0.00~20.00 mA, 4.00~20.00 mA (2 types) For current input, connect external 50 B class (0.1%) high-accuracy resistor
Non-contact
Input ON: Residual voltage max. 1 V, OFF: Leakage current max. 0.05 mA
RTD
0.2%F.S.1digit(255 ), 0.3%F.S.1digit(0 to 20 , 30 to 50 ) Below -100 for TC is 0.4%F.S.1digit (TC-K2 has same accuracy with TC-K1 and -200 to 1350 range.)
Analog
0.2%F.S.1digit(255 ), 0.3%F.S.1digit(0 to 20 , 30 to 50 ) Below -100 for TC is 0.4%F.S.1digit (TC-K2 has same accuracy with TC-K1 and -200 to 1350 range.)
Alarm output
CH1(AL1, AL2), CH2(AL1, AL2) Relay output(250 VAC/30 VDC 3 A 1 a)
Communication output
RS485 communication output(Modbus RTU protocol)

KRN50 Description


50mm Compact Hybrid Recorder & Data Logger in One Autonics is unveiling a new 50mm hybrid recorder, KRN50 Series. KRN50 Series is a 50mm compact hybrid recorder that displays measured values on LCD matrix panel after measuring a wide variety of industrial inputs including temperature and analog signals. This device records data by printing out on paper from direct thermal printer and when paper runs out, data logger function will automatically backup measured values real-time.

0 Reviews - Be the First to Review!


Warning: include(): http:// wrapper is disabled in the server configuration by allow_url_include=0 in /home/motiongu/public_html/_includes/templates/suppliers-product-reviews/check-for-review-submit.php on line 95

Warning: include(http://www.motioncontrolguide.com/_includes/templates/suppliers-product-reviews/show-review-fields.php): failed to open stream: no suitable wrapper could be found in /home/motiongu/public_html/_includes/templates/suppliers-product-reviews/check-for-review-submit.php on line 95

Warning: include(): Failed opening 'http://www.motioncontrolguide.com/_includes/templates/suppliers-product-reviews/show-review-fields.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/motiongu/public_html/_includes/templates/suppliers-product-reviews/check-for-review-submit.php on line 95

Copyright 2013-2014 MotionControlGuide.com - index - trade show index