TC3YF-11R1 Product Details

Part Number
TC3YF-11R1
DIN W72H36mm Freezing/Defrost Temperature controller
Manufacturer: Autonics
Technical Specification

Power supply
12-24VDC100-240VAC50/60Hz12-24VDC100-240VAC 5060Hz12-24VDC100-240VAC 50/60Hz
Power consumption
Max. 8W Max. 4VAMax. 8WMax. 4VAMax. 8WMax. 4VA
Character size(WxH)
7.415.0mm
Display accuracy
(PV 0.5% or 1, select the higher one) rdg 1digit
Input sensor2
NTC : Thermistor, RTD : DPt 100
Control method
ON/OFF control(Adjustment sensitivity 0.5 to 5.0, 2 to 50F variable)
Memory protection
Approx. 10 years(When using non-volatile semiconductor memory)
Dielectric strength
2000VAC 60Hz for 1 minute(between all external terminal and case)
COMP
Mechanical : Min. 20,000,000 times, Electrical : Min. 50,000 times(250VAC 5A resistive load)
FAN
Mechanical : Min. 20,000,000 times, Electrical : Min. 50,000 times(250VAC 5A resistive load)
Allowable voltage range
90 to 110% of rated voltage
Display method
7 Segment(red) LED method
Indication range
NTC : -40.0 to 99.9(40 to 212F), RTD : -99.9 to 99.9(-148 to 212F)
Sampling period
0.5sec.
Input line resistance
Allowable line resistance is max. 5 per a wire
Control output
Compressor output (250VAC 5A 1a)Compressor output (250VAC 5A 1a) Defrost output (250VAC 10A 1a)Compressor output (250VAC 5A 1a) Defrost output (250VAC 10A 1a) Evaporation-fan output (250VAC 5A 1a)
Insulation resistance
Min. 100M(at 500VDC megger)
Noise resistance
2kV R-phase, S-phase the square wave noise (pulse width: 1us) by the noise simulator
DEF
Mechanical : Min. 20,000,000 times, Electrical : Min. 100,000 times(250VAC 10A resistive load)
Mechanical
0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours

TC3YF-11R1 Description


Freezing / Defrost temperature controller TC3YF series is high reliability temperature controller to protect the object inside the chillers via compressor output so that compressor operation cycle and ON ratio can be set even if errors occurs. This series also prevents loss of frozen efficiency with defrost function to remove frozen ice or frost in the freezer, and increases the efficiency of frozen through various delay time setting.

0 Reviews - Be the First to Review!


Warning: include(): http:// wrapper is disabled in the server configuration by allow_url_include=0 in /home/motiongu/public_html/_includes/templates/suppliers-product-reviews/check-for-review-submit.php on line 95

Warning: include(http://www.motioncontrolguide.com/_includes/templates/suppliers-product-reviews/show-review-fields.php): failed to open stream: no suitable wrapper could be found in /home/motiongu/public_html/_includes/templates/suppliers-product-reviews/check-for-review-submit.php on line 95

Warning: include(): Failed opening 'http://www.motioncontrolguide.com/_includes/templates/suppliers-product-reviews/show-review-fields.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/motiongu/public_html/_includes/templates/suppliers-product-reviews/check-for-review-submit.php on line 95

Copyright 2013-2014 MotionControlGuide.com - index - trade show index